Showing the single result

  • The-Relay-Testing-Handbook_Principles-and-Practice

    The Relay Testing Handbook: Principles and Practice

    (2 customer reviews)

    Price range: $99.95 USD through $139.95 USD

    The 650+ page hardcover compilation includes most of the volumes in The Relay Testing Handbook series (1, 2, 3, 4, 5, 6, 8, & 9) and includes the following topics:

    • Electrical fundamentals including three-phase electricity, phasor diagrams, and fault types
    • Relay testing fundamentals such as static, dynamic pickup and timing tests
    • The most commonly used testing philosophies, and the most efficient and effective ones
    • How to translate digital logic used by relay manufacturers into familiar concepts
    • Best practices for creating and implementing test plans

    The The Relay Testing Handbook: Principles and Practice can be ordered as an Adobe Acrobat PDF digital download, or as a hardcover book (that also includes the Adobe Acrobat PDF digital download for free).  PDF download links will be sent via email after the order has been processed, usually the same day. See our Policies page for more details and PDF digital download license restrictions. The Relay Testing Handbook #7: End-to-End Testing is NOT included in the hardcover book. You can order the complete series here to get a discount on the hardcover book and #7 End-to-End Testing.

    SKU: TRTH-H Categories: , Tag:

    Get the Relay Testing Handbook Series Every Relay Tester Needs

    The Relay Testing Handbook: Principles and Practice

    Most electrical training handbooks available today are written by engineers who tend to focus more on electrical theory than on practical applications. Although this information is certainly important and useful, relay testing technicians who work in the field need practical training based on the actual equipment and testing scenarios they are likely to encounter on a daily basis.

    In addition to this, contemporary relay systems require modern testing techniques for both efficiency and accuracy. Because protective relays are both more powerful and more complex than they used to be, relay testing technicians require a broader knowledge base to do their jobs efficiently and effectively. The Relay Testing Handbook was created for just this reason.

    Written by an experienced relay tester, The Relay Testing Handbook Series was created with the relay testing technician in mind. Loaded with practical examples that cover equipment from a broad range of manufacturers, this handbook is an indispensable resource for relay testers of all skill levels. Eight of the nine volumes in the series are included in the hardcover book, which covers topics such as:

    • Electrical fundamentals including three-phase electricity, phasor diagrams, and fault types
    • Relay testing fundamentals such as static, dynamic pickup and timing tests
    • The most commonly used testing philosophies, and the most efficient and effective ones
    • How to translate digital logic used by relay manufacturers into familiar concepts
    • Best practices for creating and implementing test plans

    Additional chapters are dedicated to the most commonly used protective elements including:

    • Overvoltage, undervoltage, and frequency (59/27/81)
    • Time, instantaneous, and directional overcurrent (51/50/67)
    • Simple, and transformer, differential (87) testing with three or six current channels
    • Line distance (21) testing using realistic test plans to minimize setting changes

    The The Relay Testing Handbook: Principles and Practice can be ordered as an Adobe Acrobat PDF digital download, or as a hardcover book (that also includes the Adobe Acrobat PDF digital download for free).  PDF download links will be sent via email after the order has been processed, usually the same day. See our Policies page for more details and PDF digital download license restrictions. The Relay Testing Handbook #7: End-to-End Testing is NOT included in the hardcover book. You can order the complete series here to get a discount on the hardcover book and #7 End-to-End Testing.

    Download the Table of Contents, Table of Figures, and Index

    Weight 6 lbs
    Dimensions 9 × 12 × 2 in
    Format

    ,

    Number of Pages

    Trim Size

    Publisher

    Language

    ISBN-13

    OTHER HANDBOOK USERS

    Pacific Gas and Electric (PG&E), The Northern Alberta Institute of Alberta (NAIT), Tri-State Generation and Transmission, Electrical Reliability Services (Emerson/ERS), Xcel Energy, MidAmerican Energy, Arizona Public Service (APS), Northern Michigan University, Kansas City Power & Light, Tri-County Electrical Cooperative, Snohomish County PUD, USBR, Northwest Iowa Community College, POWER Testing and Energization, Inc.

    Library of Congress Number

    2 reviews for The Relay Testing Handbook: Principles and Practice

    1. Daniel de Freitas –

      I have just bought your protection relay testing set of books about a few weeks ago and I just wanted to say that I’m very impressed with it.

      I have been commissioning power systems for a few years and I wish I had found your books a while ago.

    2. Gary –

      What would you tell someone who was thinking about a purchase?

      “It’s nice to get updates and correction via email”

    Add a review

    Your email address will not be published. Required fields are marked *


    You may also like…

    • The-Complete-Relay-Testing-Handbook-Series

      The Complete Relay Testing Handbook Series

      Order The Complete Relay Testing Handbook series at one time and get both The Relay Testing Handbook:Principles and Practice hardcover book (includes books 1, 2, 3, 4, 5, 6, 8, & 9) and The Relay Testing Handbook #7: End-to End Testing.

      The 650+ page hardcover compilation includes most of the volumes in The Relay Testing Handbook series (1, 2, 3, 4, 5, 6, 8, & 9) and includes the following topics:

      • Electrical fundamentals including three-phase electricity, phasor diagrams, and fault types
      • Relay testing fundamentals such as static, dynamic pickup and timing tests
      • The most commonly used testing philosophies, and the most efficient and effective ones
      • How to translate digital logic used by relay manufacturers into familiar concepts
      • Best practices for creating and implementing test plans

      The Relay Testing Handbook: End-to-End Testing provides:

      • A basic introduction to this important testing technique
      • Step-by-step procedures for performing successful end-to-end tests
      • An overview of the most common communication-assisted protection schemes to help the reader understand how these schemes operate

      The Relay Testing Handbook: Simplified Motor Relay Testing
      If you want to learn how to test motor relays, this is the book for you.  But it is much, much more! It includes everything I’ve learned about relay testing since The Relay Testing Handbook: Principles and Practice, including step-by-step dynamic testing procedures that can be applied to any relay element with fixed-time delays. This is THE most comprehensive guide about motor relay testing AND dynamic relay testing. This book is a must read for anyone who wants to up their game from a button pusher to a true relay testing craftsman. Keep reading to learn more about dynamic testing…

      The complete series can be ordered as Adobe Acrobat PDF digital downloads, or as hardcover/soft-cover books (including free PDF downloads). PDF download links will be sent via email after the order has been processed, usually the same day.  See our Policies page for more details and PDF digital download license restrictions.

      Image Product Quantity

      The Relay Testing Handbook: Principles and Practice

      1

      The Relay Testing Handbook: Generator Relay Protection Testing

      1

      The Relay Testing Handbook: Simplified Motor Relay Testing

      1

      The Relay Testing Handbook #7: End-to-End Testing

      1
      Quantity discounts
      1-5 -0%
      6-10 -10%
      11-20 -15%
      21-50 -20%
      51+ -30%