• Home
  • /
  • Shop
  • /
  • ISBN-13: 978-1-934348-29-1
  • The Relay Testing Handbook: Generator Relay Protection Testing

    The Relay Testing Handbook: Generator Relay Protection Testing

    Price range: $119.95 USD through $149.95 USD

    Generator Relay Testing explains the most important fundamentals and shows you how to apply them when testing any generator relay with any test-set, with sections like:

    • Introduction to Generators
    • Generator Control Systems
    • Generator Diagrams
    • Getting Ready to Test
    • Element Testing Principles
    • How to Perform Acceptance, Commissioning, and Maintenance Tests

    Once you understand generator and relay testing theory, this book will show you universal, step-by-step test procedures for more than a dozen elements using modern, dynamic testing techniques.

    Generator Relay Testing can be ordered as an Adobe Acrobat PDF digital download, or as a hardcover book (that also includes the Adobe Acrobat PDF digital download for free).  PDF download links will be sent via email after the order has been processed, usually the same day. See our Policies page for more details and PDF digital download license restrictions. Over 200 pages of content and duplicate test plans are NOT included in the hardcover book due to printing limitations. We suggest you keep the PDF as a handy reference while reading the hardcover book.

    SKU: TRTH-11 Categories: , Tag:

    Learn How to Confidently Test Any Generator Relay with Any Test Set

    If you have ever performed generator relay testing, you know that there are many different elements with different operating characteristics. This can be a hard code to crack, even for experienced relay testers. But once you’ve learned how to solve the puzzle, you can confidently test any generator relay.

    Understanding how a generator relay operates in the real world is the key to easy and effective generator relay testing. Testing elements inside a generator relay becomes much easier when you apply realistic conditions with your test-set.

    The Relay Testing Handbook: Principles and Practice:

    • introduced you to relay testing,
    • gave you the theory behind the most commonly used protective relay elements, and
    • provided step-by-step testing instructions.

    This book explains the most important fundamentals and shows you how to apply them when testing any generator relay with any test-set, with sections like:

    • Introduction to Generators
    • Generator Control Systems
    • Generator Diagrams
    • Getting Ready to Test
    • Element Testing Principles
    • How to Perform Acceptance, Commissioning, and Maintenance Tests

    Once you understand generator and relay testing theory, this book will show you universal, step-by-step test procedures for these elements using modern, dynamic testing techniques:

    • Phase Distance (21)
    • Volts/Hz (V/Hz)/Over-Excitation (24)
    • Synchronizing and Synch-Check (25)
    • Under-Voltage (27)
    • 100% Stator Earth (27TN/64G2)
    • Reverse/Under-Power (32)
    • Loss of Field/Field Failure (40)
    • Negative Sequence Over-Current (46)
    • Breaker Failure (50BF)
    • Inadvertent Energizing (50/27)
    • Voltage Control/Restraint Over-Current (51V)
    • Neutral Over-Voltage (59N/64G)
    • Fuse Loss/Failure (60FL)
    • Out-of-Step (78)
    • Under/Over Frequency (81)
    • Phase Differential (87)

    Whether you’re just getting started with generator relay testing or have been frustrated by puzzling through the different elements and operating characteristics, this book will help you take your relay testing skills to the next level.

    Weight N/A
    Dimensions N/A
    Format

    ,

    ISBN-13

    ,

    Language

    Number of Pages

    Publisher

    Trim Size

    Reviews

    There are no reviews yet.

    Be the first to review “The Relay Testing Handbook: Generator Relay Protection Testing”

    Your email address will not be published. Required fields are marked *

    You may also like…

    • The-Complete-Relay-Testing-Handbook-Series

      The Complete Relay Testing Handbook Series

      Order The Complete Relay Testing Handbook series at one time and get both The Relay Testing Handbook:Principles and Practice hardcover book (includes books 1, 2, 3, 4, 5, 6, 8, & 9) and The Relay Testing Handbook #7: End-to End Testing.

      The 650+ page hardcover compilation includes most of the volumes in The Relay Testing Handbook series (1, 2, 3, 4, 5, 6, 8, & 9) and includes the following topics:

      • Electrical fundamentals including three-phase electricity, phasor diagrams, and fault types
      • Relay testing fundamentals such as static, dynamic pickup and timing tests
      • The most commonly used testing philosophies, and the most efficient and effective ones
      • How to translate digital logic used by relay manufacturers into familiar concepts
      • Best practices for creating and implementing test plans

      The Relay Testing Handbook: End-to-End Testing provides:

      • A basic introduction to this important testing technique
      • Step-by-step procedures for performing successful end-to-end tests
      • An overview of the most common communication-assisted protection schemes to help the reader understand how these schemes operate

      The Relay Testing Handbook: Simplified Motor Relay Testing
      If you want to learn how to test motor relays, this is the book for you.  But it is much, much more! It includes everything I’ve learned about relay testing since The Relay Testing Handbook: Principles and Practiceincluding step-by-step dynamic testing procedures that can be applied to any relay element with fixed-time delays. This is THE most comprehensive guide about motor relay testing AND dynamic relay testing. This book is a must read for anyone who wants to up their game from a button pusher to a true relay testing craftsman. Keep reading to learn more about dynamic testing…

      The complete series can be ordered as Adobe Acrobat PDF digital downloads, or as hardcover/soft-cover books (including free PDF downloads). PDF download links will be sent via email after the order has been processed, usually the same day.  See our Policies page for more details and PDF digital download license restrictions.

      Image Product Quantity

      The Relay Testing Handbook: Principles and Practice

      1

      The Relay Testing Handbook: Generator Relay Protection Testing

      1

      The Relay Testing Handbook: Simplified Motor Relay Testing

      1

      The Relay Testing Handbook #7: End-to-End Testing

      1
      Quantity discounts
      1-5 -0%
      6-10 -10%
      11-20 -15%
      21-50 -20%
      51+ -30%