  • The Relay Testing Handbook #7: End-to-End Testing – PDF Only

The Relay Testing Handbook #7: End-to-End Testing – PDF Only

$24.95 USD

Quantity discounts
1-5 -0%
6-10 -10%
11-20 -15%
21-50 -20%
51+ -30%

 The End-to-End Testing Manual that Every Technician Needs

The Relay Testing Handbook: End-to-End Testing provides both a basic introduction and a clear, step-by-step procedure for performing end-to-end tests in the field. You’ll also get an overview of the most commonly applied communication-assisted protection schemes so you will know how they function when performing your end-to-end tests.

This volume of The Relay Testing Handbook series is designed to teach relay testers the following information:

  • The fundamentals of end-to-end testing
  • Why end-to-end testing is used
  • How end-to-end testing works in real life
  • When and where to perform an end-to-end test

The primary goal of the end-to-end testing handbook is to provide relay testers with enough information to perform these tests in the field. To do this, practical examples are provided throughout the text so you can apply your new knowledge in real-world situations. In addition to the basic principles and philosophies behind end-to-end testing, some of the practical resources you can expect to get in this volume include:

  • Detailed end-to-end testing procedures
  • Descriptions of the most common protection schemes, such as:
    • Direct Under-Reaching Transfer Trip (DUTT)
    • Permissive Over-Reaching Transfer Trip (POTT)
    • Directional Comparison Unblocking (DCUB)
    • Permissive Under-Reaching Transfer Trip (PUTT)
    • Directional Comparison Blocking (DCB)
    • Line Differential (Pilot Wire, Charge Comparison, Traditional Differential, and the Alpha Plane)

The The Relay Testing Handbook #7: End-to-End Testing can be ordered as a soft-cover book, Adobe Acrobat PDF digital download, or both.  PDF download links will be sent via email after the order has been processed.  Usually the same day.  See our Policies page for more details and PDF digital download license restrictions. This book is NOT included in hardcover book The Relay Testing Handbook: Principles and Practice. You can order the complete series here to get a discount.


Discover more from Valence Electrical Training Services

Subscribe to get the latest posts sent to your email.

Format

,

Trim Size

Number of Pages

Publisher

Language

ISBN-13

Library of Congress Number

Reviews

There are no reviews yet.

Be the first to review “The Relay Testing Handbook #7: End-to-End Testing – PDF Only”

Your email address will not be published. Required fields are marked *