  • The New How to Test Voltage Protection Online Training Seminar is Now in Post-Production

The New How to Test Voltage Protection Online Training Seminar is Now in Post-Production

All of the videos for this seminar have been recorded and we’re currently sending pre-release discounts to students, customers, and people on our mailing list before we release it to the public in March 2025:

Lesson 1:) Introduction to Voltage Transformers (PTs or VTs)
  • Introduction to VTs and VT Ratios
  • Introduction to VT Burden
  • Introduction to CVTs
  • How to Measure Voltage Basics
  • Why the Voltage Drops During a Fault
  • How to Draw and Label AC Measurements
  • Introduction to 3-Phase AC Voltage Measurements
  • How to Simulate AC Voltages
  • All the Extras – Downloads, Credits, and Additional Training Options
Lesson 2: How to Test OverVoltage (59-Element) Protection Inside an IED/Relay
  • Introduction to OverVoltage (59) Protection
  • Understanding How the 59-Element Works Inside an IED/Relay
  • How to Perform a Manual 59-Element Pickup Test in an IED/Relay
  • How to Perform a 59-Element Step Ramp Pickup Test in an IED/Relay
  • How to Perform a 59-Element Pulse Ramp Pickup Test in an IED/Relay
  • How to Perform a 59-Element Time Test in an IED/Relay
  • How to Perform a 59-Element Dynamic Pickup/Timing Test in an IED/Relay
  • How to Perform a Modern 59-Element Test
  • All the Extras – Downloads, Credits, and Additional Training Options
Lesson 3: Symmetrical Components For Relay Testers
  • Introduction to Symmetrical Components
  • Symmetrical Components for Relay Testers
  •  Introduction to Phasor Math
    • How to Add Phasors Graphiccally
    • How to Add Phasors with Math
    • How to Multiply Phasors
  • How to Calculate Positive-Sequence Voltage
  • Introduction to Positive-Sequence Voltage Protection in IEDs
  • How to Test  Positive-Sequence Voltage Protection in IEDs
  • How to Calculate Negative-Sequence Voltage
  • Introduction to Negative-Sequence Voltage Protection in IEDs
  • How to Test  Negative-Sequence Voltage Protection in IEDs
  • How to Calculate Zero-Sequence Voltage
  • Introduction to Zero-Sequence Voltage Protection in IEDs
  • How to Test  Zero-Sequence Voltage Protection in IEDs
  • All the Extras – Downloads, Credits, and Additional Training Options
Lesson 4: How to Test UnderVoltage Elements (27)
  • Introduction to UnderVoltage (27) Protection
  • Understanding How the 27-Element Works Inside an IED/Relay
  • How to Build a UnderVoltage (27) Test Plan
  • How to Perform a Manual UnderVoltage (27) Pickup Test
  • How to Perform a Step Ramp UnderVoltage (27) Pickup Test
  • How to Perform a Pulse Ramp UnderVoltage (27) Pickup Test
  • How to Perform a Dynamic UnderVoltage (27) Pickup Test
  • How to Perform an UnderVoltage (27) Timing Test
  • Putting it All Together – Several Different  27-UnderVoltage Test Plan
  • All the Extras – Downloads, Credits, and Additional Training Options
Lesson 5: How to Test IEDs/Relays With Delta PT Connections
  • Three-Phase Voltage Measurement Reminder
  • Understanding Phase-Phase Voltage Measurements
  • Understanding Open-Delta Voltage
  • Understanding Open-Delta Voltage Angles
  • How to Connect Your Test-Set to Open-Delta Relays
  • How To Perform Open-Delta Meter Tests
  • How To Perform Open-Delta Over-Voltage Tests
  • How To Perform Under-Delta Over-Voltage Tests
  • An Apology to General Electric – I screwed Up
  • How to Connect Your Test-Set to Open-Delta Relays Like an E-M Tester
  • How to Perform E-M Style Open-Delta Tests
  • All the Extras – Downloads, Credits, and Additional Training Options
Lesson 6: How to Test IEDs/Relays With Wye/Broken-Delta VT Connections
  • Introduction to Wye/Broken Delta Connected VTs
  • Testing Wye/Broken Delta Protective Elements
  • All the Extras – Downloads, Credits, and Additional Training Options

Discover more from Valence Electrical Training Services

Subscribe to get the latest posts sent to your email.