It would appear that everyone is either having no issues with ABB relays or ignoring them in hopes that they will go away. That said, is anyone using a Doble 6150 w/Protest and have good results? nu...
Continue readingpeace be with you all Can you give me an idea, how to test SIEMENS 7sj622 directional o.c and directional e.f fault relay by using omicron .freja or any Numerical testing instrument? regardes mohammad
Continue readingI am attempting to test the Negative Sequence Overcurrent on a 351 and 351S with an Omicron test set and my test plans just don’t seem to be working very well. I have managed to get a one shot to
Continue readingCable: 9-pin to 9-pin RS-232 Straight Through Software: Futura+ Communicator Settings: Default Settings Link: Direct Connection Device Address: 0001 Communications
Continue readingThis post is pretty old. I suggest you check this post to get a better idea of my thoughts on test-sets. https://relaytraining.com/what-is-the-best-protective-relay-test-set/ I understand Chris has
Continue readingThe DC Power supply to the relay quit in the middle of a setting download and when the power was restored, the relay EEprom failed. I was able to communicate with the relay (at a different BAUD rate)
Continue readingThis was a nice surprise for me. Older versions of the SR-745 have a maximum voltage of 200kV. If you use newer software to set the relay, it indicates a maximum voltage of 2000.0 kV. If a voltage
Continue readinghttp://www.beckwithelectric.com/ Beckwith M-3425 Generator protection Cable: 9-pin to 9-pin RS-232 Null Modem Software: 3820A IPScom Communications Software Software Default Settings PC Port: Com1 (Varies
Continue readingBasler GPS100 Relay Cable: 9-pin to 9-pin RS-232 Straight through Software: Basler Bestcomms software for GPS100 Software Default Settings Comm Port: 1 Varies by Computer (Doesn’t
Continue readinghttp://www.geindustrial.com/cwc/product … lang=en_US MIF: http://www.geindustrial.com/cwc/product … lang=en_US Cable: 9-pin to 9-pin RS-232 Straight Through Software: GE_NESIS M+PC – http://www.geindustrial.com/publibrary/
Continue readinghttp://www.geindustrial.com/cwc/product … lang=en_US GE LPS http://www.geindustrial.com/cwc/product … lang=en_US Cable: 9-pin to 9-pin RS-232 Null Modem Software: EnerVista ALPS/LPS/LPS-O
Continue readingMIV: Cable: 9-pin to 9-pin RS-232 Straight Through Software: GE_NESIS M+PC – Software Default Settings Connection: Baud Rate: Direct Connection Port: 1 (Varies by computer) Parity: No Parity Data
Continue readinghttp://www.geindustrial.com/cwc/products?famid=31&lang=en_US DGP: http://www.geindustrial.com/cwc/products?pnlid=6&famid=31&catid=168&id=dgp&lang=en_US Cable: 9-pin to 9-pin RS-232
Continue readingThis has been bothering myself and some of my employees for a while. GE Quads are extended on the reach axis by the k factor of the relay, settings engineers that we have been working for are basically
Continue reading