Current Transformer Testing (CT)

I wrote an article for the NETA World magazine in 2004 that covers several different manual techniques for Current Transformer Testing that should help even the most experienced technicians.  Here’s

Continue reading

Testing Basler BE1-47N Negative Sequence Voltage Relays

Testing more complicated elements that use a percentage or ratio between values can be difficult if you cannot properly define all of the values in the equation.  It doesn’t help that different

Continue reading

Real World Problem With an SEL-300G Synch-Check

Here is a story from one of our Customers at Manta Test Systems: “I had to troubleshoot a Schweitzer SEL-300G relay yesterday that had the (25) Sync-Check element enabled, but wouldn’t assert the

Continue reading

SEL-451 and Frequency Testing Issue

A customer was having problems timing a SEL-451 with a delay setting of 8 cycles. He was measuring a 12 cycle delay when transitioning from 59.5 to 58.5 Hz. If you look at the spec sheet, the SEL-451 frequency

Continue reading

Connect to a Electro Industries Futura+ Series CPU1000

Cable:        9-pin to 9-pin RS-232 Straight Through Software:   Futura+ Communicator Settings:     Default Settings Link:          Direct Connection Device Address: 0001 Communications

Continue reading

What Relay Test Equipment Do You Use and Why?

This post is pretty old.  I suggest you check this post to get a better idea of my thoughts on test-sets.  https://relaytraining.com/what-is-the-best-protective-relay-test-set/ I understand Chris has

Continue reading

Reset SEL relays to Factory Defaults

The DC Power supply to the relay quit in the middle of a setting download and when the power was restored, the relay EEprom failed.  I was able to communicate with the relay (at a different BAUD rate)

Continue reading

Possible Winding Voltages Setup Issue With GE Multilin 745 Transformer Management Relay

This was a nice surprise for me.  Older versions of the SR-745 have a maximum voltage of 200kV.  If you use newer software to set the relay, it indicates a maximum voltage of 2000.0 kV.  If a voltage

Continue reading

How to Connect to a Beckwith Electric M-3425 Relay

http://www.beckwithelectric.com/ Beckwith M-3425 Generator protection Cable: 9-pin to 9-pin RS-232 Null Modem Software: 3820A IPScom Communications Software Software Default Settings PC Port: Com1 (Varies

Continue reading

How to Connect to a BE1-GPS100

  Basler GPS100 Relay   Cable: 9-pin to 9-pin RS-232 Straight through Software: Basler Bestcomms software for GPS100 Software Default Settings Comm Port: 1 Varies by Computer (Doesn’t

Continue reading

How to Connect to a GE MIF Relay

http://www.geindustrial.com/cwc/product … lang=en_US MIF: http://www.geindustrial.com/cwc/product … lang=en_US Cable: 9-pin to 9-pin RS-232 Straight Through Software: GE_NESIS M+PC – http://www.geindustrial.com/publibrary/

Continue reading

How to Connect to a GE LPS Relay

http://www.geindustrial.com/cwc/product … lang=en_US GE LPS http://www.geindustrial.com/cwc/product … lang=en_US Cable: 9-pin to 9-pin RS-232 Null Modem Software: EnerVista ALPS/LPS/LPS-O

Continue reading

How to Connect to a GE MIV Relay

MIV: Cable: 9-pin to 9-pin RS-232 Straight Through Software: GE_NESIS M+PC – Software Default Settings Connection: Baud Rate: Direct Connection Port: 1 (Varies by computer) Parity: No Parity Data

Continue reading

How to Connect to a GE DGP Relay with Testing Tips

http://www.geindustrial.com/cwc/products?famid=31&lang=en_US DGP: http://www.geindustrial.com/cwc/products?pnlid=6&famid=31&catid=168&id=dgp&lang=en_US Cable: 9-pin to 9-pin RS-232

Continue reading

Question about QUADS for GE L90 and D60

This has been bothering myself and some of my employees for a while.  GE Quads are extended on the reach axis by the k factor of the relay, settings engineers that we have been working for are basically

Continue reading