All posts by Chris Werstiuk

2018 Hands-On Relay School Enrollment Now Open

Want to get the best relay training possible? Sign up for the 35th annual Hands-On Relay School in Pullman, Washington happening March 12-16, 2018. They fill up fast, so you should sign up today! https://cm.wsu.edu/ehome/index.php?eventid=268868& This

Continue reading

How to Perform Dynamic Relay Testing on Digital Relays

If you’ve read anything about relay testing written in the last ten years or so, you’ll see a pattern; No-one is talking about the traditional pickup and timing tests most relay testers (and

Continue reading

Why Does My Open-Delta Connected Phasor Diagram Look Weird?

Meter tests on protected relays connected to open-delta connected PTs can be very confusing. I know I spent a LOT of time trying to figure out the values reported by my first open-delta connected relay

Continue reading

Why Do Traditional Line Distance Protection Relay Testing Procedures FAIL on Digital Relays?

Traditional line distance relay testing procedures (MTA, Reach, and Timing) are a great way to test electro-mechanical relays and learn how line impedance relays operate; but they are inefficient, ineffective,

Continue reading

Overcurrent Relay Testing Online Seminar – Under Construction

We need your help with our next online seminar about overcurrent relay testing. What would you like to see in an online seminar about overcurrent relays? Our current rough outline includes: Why Do We

Continue reading

Coming Soon! The Relay Testing Handbook: Simplified Motor Protection Relay Testing

Start by understanding the general operating characteristics of motors and their control schemes. Review the documentation to make sure everything is designed to operate correctly. Connect your test-set

Continue reading

How to Understand and Determine Phase Rotation in a Power System

Understanding phase rotation is vital when connecting two systems together because the results can be catastrophic if someone doesn’t understand how to interpret phase rotation drawings. You would think

Continue reading

Understanding Permissive Under-Reaching Transfer Trip (PUTT) Communication Assisted Trip Schemes Video

Here is the latest video describing the Permissive Under-Reaching Transfer Trip Communication-Assisted Trip Schemes used in modern distance protection. You can follow along with this animation via the

Continue reading

Help with 27/47/59N Protection in an SEL-387E

A reader has requested some help for an upcoming project: I will be reviewing some relay testing that needs to performed shortly and I am trying to understand how the 27/47/59N (within a SEL 387E) relay

Continue reading

How to Measure Phase Angles with a Phase Angle Meter

I’ve noticed that many students don’t seem to have experience with phase angle meters, and they can’t guess what a phase angle meter would measure in simple circuit. This knowledge is CRITICAL if

Continue reading

Valence will be at the 34th Annual Hands-On Relay School

Chris will be at the 34th Annual Hands-On Relay School this year. Stop by the Suppliers Showcase on Tuesday evening to meet the author of The Relay Testing Handbook Series, or check out our collection

Continue reading

How To Communicate with a Test-Set or Relay

Sometimes the hardest part of relay testing is getting your laptop to talk to the relay or test-set. There are two primary communication methods: Serial Connections Serial communication is the most

Continue reading

Frequency Response and the Power System

Here’s an excellent video on frequency response in the grid from NERC. I often tell my students that renewables are making the power system less stable and this video explains part of the issue....

Continue reading

What Was Your Electrical Epiphany?

The next generation of relay testers need your help! We’re almost finished our “How to Test Protective Relays” Online Seminar and we’re starting to write the next online training

Continue reading

High Impedance Busbar Differential Protection

We covered the basic operating principles of high impedance busbar differential protection in our previous post, I Want to Know How a High Impedance Differential Scheme Works. You should read that post

Continue reading